Performance:
2.1 Sensitivity
6E-15 Tesla
5µA at 1 meter (33kHz)
2.2 Dynamic range
140dB rms/ÖHz
2.3 Selectivity
120dB/Hz
2.4 Depth measurement precision1
± 3%
2.5 Locate accuracy
± 5% of depth
2.6 Active Locate filter bandwidth
± 3Hz, 0 < 1kHz
± 10Hz, ³ 1kHz
2.7 Start-up time
<1 second
2.8 Maximum depth readout2
Metric:Cable / Pipe: 30m Sonde: 19.5m
Imperial: Cable / Pipe: 98′ Sonde: 64′
Radiodetection RD 8100 Ground Penetrating Radar
The RD8100 is RadioDetection’s most up to date locator range. A unique arrangement of 5 custom manufactured ground antennas allow the level of precision to be monitored and changed to suit the needs of the user, depending on the job in hand.
Radiodetection RD 8100 Ground Penetrating Radar
Precision by design
Accurate surveying with integrated or external GPS
Durable, sealed design – IP65
Save time on site with iLOC remote transmitter control
Shallow locate warning – StrikeAlert™ in active & passive locating
Locate in difficult environments with Dynamic Overload Protection
eCert – Certified confidence without downtime
Enhanced Self-Test
Set-up, calibrate and update your locator from a PC – RD Manager PC software
Specification
Radiodetection RD8100 gpr ground penetrating radar Utility cable and pipe locator range underground pipeline detector
Product Summary:
1.1 Product Descriptions
Multi-purpose Precision Locator Cable and Pipe Locator
Locate System Receiver
Multi-function Precision Locator
1.2 Intended Use
Locating the position / path of buried cables and pipes
Detecting and pinpointing insulation faults on buried cables and pipes Creating survey records of buried cables and pipes locations
1.3 Standard Equipment
Locator Quickstart guide
Mini USB 2.0 compliant data cable
Performance:
2.1 Sensitivity
6E-15 Tesla
5µA at 1 meter (33kHz)
2.2 Dynamic range
140dB rms/ÖHz
2.3 Selectivity
120dB/Hz
2.4 Depth measurement precision1
± 3%
2.5 Locate accuracy
± 5% of depth
2.6 Active Locate filter bandwidth
± 3Hz, 0 < 1kHz
± 10Hz, ³ 1kHz
2.7 Start-up time
<1 second
2.8 Maximum depth readout2
Metric:Cable / Pipe: 30m Sonde: 19.5m
Imperial: Cable / Pipe: 98′ Sonde: 64′